why does my air conditioner freeze up with ice

Why is My Air Conditioning Unit Frozen? We are likely going to experience 90 degree temperatures by the end of the week in Durham, NC. Though it seems counterintuitive, as summer heats up, a malfunctioning HVAC unit can accumulate ice buildup that will harm itsPperformance. Why is your air conditioner freezing up in the heat of summer? Below are a few common causes for HVAC freeze ups and what you can do about it. Your air conditioning system relies on a delicate balance of systems working together to remove warm, humid air from your home and replace it with cooled air from outside. If one of these systems is not functioning properly, it can affect the entire unit. In other words, there are several potential causes for your icy HVAC system:
When your refrigerant is low, the evaporator coil will overact and can drop below freezing. When the evaporator coil temperature drops below freezing, moisture in the air will turn to ice and build up on your unit. If the refrigerant in your unit is low, it means there is a leak somewhere in your unit. You should never have to replace refrigerant. P HVAC technician if your unit is losing refrigerant. If the airflow to your outdoor unit is restricted, warm air from your home may be preventedPfrom passing over the evaporator coil.


In this case, rather than exchanging and balancing warm air from inside your home with cooled airPfrom outdoors, the evaporator coil will over compensate by dropping its temperature below freezing. Dirty, old air filters. Closed indoor vents. Ductwork laden with dirt and debris. Leaves, sticks, and other debris on your outdoor unit. Fencing and shrubbery too close to your unit (within two feet). Load calculation is the process by which HVAC units are sized for maximum effectiveness. Load calculation is required whenever a new air conditioning system is installed; however, if it was performed incorrectly, or if you built an air conditioned addition since load calculation was last performed, yourPunit mayPbe too small to meet your homes needs. The evaporator coil in an undersized unit may overcompensate for its work load by lowering the temperature below freezing, which will lead to a buildup of ice. In addition to freezing up, an undersized unit may run constantly, but fail to cool your home to the temperature on which the thermostat is set. If you suspect your unit is undersized,. Other mechanical failures could lead to your unit freezing. If you have concerns about your air conditioning systems performance, as soon as possible. Small issues can quickly turn into major, costly repairs. 1) Allow the system to defrost completely. 2) Check for leaking refrigerant.


If there are visible signs of leakage, call a professional immediately. 3) Change your air filters regularly. Check them at least monthly and change them as often as they are dirty. 4) Correct any other clearance issues: Remove shrubbery and fencing that blocks airflow. Clean any debris from storms, grass clippings, etc. Open indoor air vents. Have ducts cleaned and maintained. 5) Sign up for a maintenance plans. ensure your air conditioning system is always ready to perform and that minor issues are corrected before they become major, costly repairs. The cause of this problem could be as simple as a dirty air filter or it could be crimped, disconnected ductwork or even improperly-sized ductwork. Б The refrigerant is not being metered properly into the cooling coil, (too little is being released). A clogged capillary tube or a frozen, dirty, stuck thermostatic expansion valve can cause this trouble. (the Evaporator Coil)? can block or reduce air flow across the cooling coil, leading to coil frost. This is the first component a homeowner should check since the cleaning and replacing the air filter, is so easy. assembly: an air handler blower unit that is not moving as much air as it should will be blowing too little air across the evaporator coil.


This is a less likely but possible cause of frost build-up on the cooling coil. : When an air conditioning or refrigeration unit evaporator coil becomes sufficiently blocked with debris as to slow down the air flow enough, the coil may actually become so cold that the condensate forming on its surface freezes, completely blocking the coil. Б The refrigerant charge is too low. If there is a refrigerant leak, the first symptom may be coil icing; but later as refrigerant continues to be lost, all cooling may be lost and the coil will no longer be frosted or iced over. It's better to find and fix the refrigerant leak. or frost. To eliminate the ice or frost, turn the unit to. The unit should fairly quickly ( 5 - 15 minutes). Then, run the unit in mode until the coils or vents are dry or nearly dry. are dry, turn the, but set the to start. The compressor will run until the in the room reaches the set point, and then cycle off. off, any ice that may have accumulated on the coils or around the vents melts. Over time, gradually the temperature setting a few degrees at a time, so that the continues to cycle on and off, until you reach the temperature you want.